FBC logo - white

 

ESA710
Electrical Safety Analyzer

Our easiest-to-use electrical safety analyzer, ever.

Front right view of ESA710

Key Features

EAS710 - Small and Portable

Small and Portable

Run procedures on the go

ESA710 - Auxiliary Battery

Auxiliary Battery

Eliminate power on/off between testing equipment

ESA710 - Touchscreen

Touchscreen

Complete PMs quickly with the intuitive interface

ESA710 - Run Procedures

Run Procedures without a PC

OneQA workflow automation software

Meet the ESA710 Electrical Safety Analyzer

The ESA710 prioritizes workflow accuracy and efficiency. It sports a 5" color LCD touchscreen and a user-friendly interface for intuitive device navigation. The unit even provides visual onscreen instructions during procedures and illuminating LED lights to guide users where and when to make connections. Embrace the ESA710 Electrical Safety Analyzer for your organization today.

ADVANCED FUNCTIONALITY AND USER-FRIENDLY INTERFACE

Streamlined Electrical Safety Testing

The ESA710 Electrical Safety Analyzer revolutionizes automated testing by offering a compact, yet functional design. The tool is particularly useful for healthcare technology management professionals who require portability without sacrificing functionality. It enables users to perform a range of functions, from basic troubleshooting to comprehensive analysis. This makes the ESA710 a game-changer for electrical safety testing on medical equipment, whether in the field or within facilities. The analyzer prioritizes workflow accuracy and efficiency, boasting a 5" color LCD touchscreen and a user-friendly interface for easy device navigation.

ESA710 Electrical Safety Analyzer
ESA710 Electrical Safety Testing Made Easy

GUIDED WORKFLOW AND LED ILLUMINATION

Simplified Procedures with Visual Aids

The ESA710 is not just about performing functions; it's about guiding the user through each step. The device provides visual onscreen instructions during procedures, making it easier for users to understand and follow the process. It even comes with illuminating LED lights to guide users where and when to make connections.

RUGGED DESIGN AND GLOBAL SUPPORT

Durable, Reliable, and Supported Worldwide

The ESA710 is rigorously tested for rugged field applications. It comes with CE and CSA certification, ensuring Fluke-quality ruggedness for long-term reliability. In case of any unexpected costs, a comprehensive service and coverage program, the Protect+ Program, ensures users enjoy precision, compliance, and total peace of mind. To top it all, ESA710 is backed by a global support network that delivers prompt service and peace of mind to Fluke Biomedical customers worldwide.

ESA710 Test on the go
OneQA

Workflow automation software

With integrated OneQA software, running tests from the ESA710 is fast and easy. Testing and documenting results is fully automated saving you valuable time while enhancing accuracy.

 

Learn more about OneQA

OneQA enabled

OneQA Enabled

Workflow automation made easy

The ESA710 comes integrated with OneQA software. Testing and documenting results is fully automated saving you valuable time while increasing accuracy. OneQA allows users to customize pre-built procedures on ESA710, results are automatically saved on the device with the option of syncing to your PC simultaneously. Completing your PMs has been simplified with our intuitive user interface.

Learn more about OneQA

OneQA Enabled

Workflow Automation

FeaturesBasicComplete
CostIncludedSpeak to a specialist
Users1Unlimited
AutomationESA710ESA710
IDA-6
Legacy Electrical Safety Analyzers   
Defibrillator Analyzers   
Ventilator Analyzers   
Patient Simulators
Active Procedures5Unlimited
Pre-Built and Customizable Procedures
Green checkbox
Green checkbox
Supports offline mode
Green checkbox
Green checkbox
Standard Compliance Ready Test Reports (PDF)
Green checkbox
Green checkbox
CMMS Connectivity--
Green checkbox
Customize Data Download--
Green checkbox
Permissions based on user roles--
Green checkbox

Resources

ESA710 Datasheet

PDF

ESA700 Series Quick Start guide

PDF

ESA710 User Manual

PDF

ESA710/OneQA Quick Start Guide

PDF

Specifications

General Specifications
Safety standard compliancelEC 61010-1: Overvoltage category II, pollution degree 2
IEC 61010-2-034: Measurement CAT II 300 V
Dimensions (w x d x h)214 x 207 x 92 mm (8.4 x 8.1 x 3.6 inches)
Weight1.3 kg (2.7 pounds)
Ingress protectionIP40 per IEC 60529, excluding equipment outlet
Operating temperature0 to +35 °C (+50 to +95 °F)
Operating humidity10-90 %, non-condensing
Storage temperature-20 to +60 °C (-4 to+ 140 °F)
Storage humidity5-95 %, non-condensing
Altitude100-127 V ac mains voltage and ≤ 150 V on input jacks: ≤ 5000 m
200-240 V ac mains voltage and ≤ 300 V on input jacks: ≤ 2000 m
Battery lifeUp to 2 h
Connectivity1 x USB-C for PC communication, 2 x USB-A for peripherals
Display5-inch touchscreen
Data storage> 10 000 measurements
Power (region dependent)190-132 V ac, 20 A MAX, 47-63 Hz
90-132 V ac & 180-264 V ac, 15 A MAX, 47-63 Hz
90-132 V ac & 180-264 V ac, 16 A MAX, 47-63 Hz
Note: The supply mains voltage and frequency are continuously monitored. If a deviation from specification is detected, measurements are stopped, and a message is displayed until the user confirms.
CSA approval
US version,
90-132 V ac, 20 A MAX, 47-63 Hz
CSA approved
NEMA 6-15 version,
90-132 V ac & 180-264 V ac,
15 A MAX, 47-63 Hz
CSA approved
Electromagnetic Compatibility (EMC)
See users manual for more information.
Measurement Specifications
Mains voltage
Range0-264 V ac rms, limited by power specification
Accuracy±(2 % + 0.2 V)
Point to point voltage
Range0-300 V ac rms, limited by altitude specification
Accuracy±(2 % + 0.2 V)
Protective earth resistance & Point to point resistance
Range0-20 Ω
Accuracy±(1 % + 0.01 Ω) at ≤ 2 Ω
±(1 % + 0.1 Ω) at >2 Ω
Test currentSquare wave of at least ±200 mA for ≤ 2 Ω
Open circuit voltageMax ±24 V
Equipment Current 
Range0-20 A ac rms, limited by power specification
Accuracy±(5 % + 0.05 A)
Max duty cycle0-10 A: continuous
10-15 A: 7 min on/3 min off
15-20 A: 5 min on/5 min off
Note: Equipment outlet will be turned off if max duty cycle is exceeded. 
Leakage Current
Modesac + dc (true rms), ac only, dc only
Mains on applied part leakage test: ac only
Patient loadANSI/AAMI ES1:1993
Crest factor≤2
Range0 µA - 20 mA
Accuracydc & 20 Hz - 0.5 kHz: ±(1 % + 1 µA)
0.5 kHz - 50 kHz: ±(2.5 % + 1 µA)
50 kHz - 1 MHz: ±(5 % + 1 µA)
Mains on applied part
Test voltageMains voltage ±5 %
Current limit1 mA ± 25 % at 115 V for AAMI ES1, NFPA 99
Additional uncertaintyUp to ±2 µA for 120 V, up to ±4 µA for 230 V
Insulation Resistance
Test voltage 250 V dc and 500 V dc
Range0.1-100 MΩ
Accuracy±(2 % + 0.2 MΩ) at ≤ 10 MΩ
±(7.5 % + 0.2 MΩ) at >10 MΩ
Test voltage accuracy+20 % / -0 %
Test voltage 50 V dc and 100 V dc
Range0.1-20 MΩ
Accuracy±(10 % + 0.2 MΩ)
Test voltage accuracy+30 % / -0 %
Short-circuit current2 mA ± 0.25 mA
Maximum load capacitance2 µF
ECG simulation
Frequency accuracy±2 %
Amplitude accuracy±5 %, for 2 Hz square wave
Waveforms
ECG complex30, 60, 120, 180 and 240 BPM
Square wave0.125 and 2 Hz, 50 % duty cycle
Triangle wave2 Hz
Pulse, 63 ms30 and 60 BPM
Ventricular fibrillation
Respiration simulation
RateApnea (0 BrPM) and 10-100 BrPM in 10 BrPM steps
WaveformsNormal
Inspiration : expiration ratio1:1
Impedance baseline1000 Ω ± 5 % between leads
Impedance variation(Δ)1 ± 0.15 Ω
Respiration leadLL or LA, user selectable

Electrical Safety Analyzers product features

Key Features
Front right view of ESA710

ESA710

ESA615 product image

ESA615

ESA614

ESA612

ESA612

OneQA integrationEnabledCompatibleCompatibleCompatible
HandheldGreen checkboxGreen checkboxGreen checkboxGreen checkbox
TouchscreenGreen checkbox
Battery operatedGreen checkbox
Preferred analyzer for which standardANSI/AAMI, NFPA 99IEC60601-1 2nd and 3rd edition, ANSI/AAMI (NFPA 99), IEC62353, AS/NZS 3551ANSI/AAMI, NFPA 99IEC60601-1 2nd and 3rd edition, ANSI/AAMI (NFPA 99), IEC62353, AS/NZS 3551
ECG simulationGreen checkboxGreen checkboxGreen checkboxGreen checkbox
RespirationGreen checkbox
Applied parts posts10555
Weight2.6 lbs3.5 lbs3.5 lbs3.5 lbs

 

Discover the difference!

 
Fill out this form to get pricing and a demo.
Your regional sales representative will be in touch with you.

We regret that the current U.S. Export Regulations prohibit the sale of our products to U.S. embargoed countries. We must, therefore, decline any request for our products.

Copyright ©2024 Fluke